Summary for Test 2015-04-17-9-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 209864 DEA: 043G1204 EFIS: 0400021276 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-128-1.8 |
| Award Date | 12/12/2014 |
| Closeout Date | 06/29/2016 |
| Work Description | CONSTRUCT SOLDIER PILE WALL AND PLACE CULVERT. |
| Location Description | SONOMA COUNTY NEAR CLOVERDALE ABOUT 3.1 MILES WEST OF NORTH CLOVERDALE BOULEVARD |
| QA Service Level | 1 (Verified on 01/22/2015) |
Sample Information
| Sample Taken Date | 04/17/2015 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2015 |
| Sample type | Verification | A brief description of the sample | concrete cylinders |
| The quantity of what the sample constitutes | 2 concrete cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Acton |
| Title of sampler | SR | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | field | Transportation Laboratory (TL) Number | 059148 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
| Structure name | Unknown | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 9796 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | na |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | field | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-04-17-9
DIME Test ID: 2015-04-17-9-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-05-15
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mullins
Date of test: 05/15/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 128166 lb
Maximum load on cylinder 2: 127183 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4548.1 psi
Compressive strength of cylinder 2: 4498.9 psi
Compressive strength (to nearest 10 psi): 4520 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 5/15/2015 ✔