Summary for Test 2020-11-13-9-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 213764 DEA: 080F0304 EFIS: 0800020358 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-60-R0.7/R3.0 |
| Award Date | 03/07/2019 |
| Closeout Date | 07/27/2023 |
| Work Description | REMOVE AND REPLACE THREE OVERCROSSING BRIDGES ON ROUTE 60 |
| Location Description | IN SAN BERNARDINO COUNTY IN AND NEAR CHINO AT VARIOUS LOCATIONS FROM O.1 MILE WEST OF PIPELINE AVENUE OVERCROSSING TO 0.1 MILE EAST OF BENSON AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 05/01/2019) |
Sample Information
| Sample Taken Date | 11/13/2020 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/18/2020 | Sample type | Quality Assurance |
| A brief description of the sample | concrete cylinders | The quantity of what the sample constitutes | 35 CY |
| From where was the sample collected | Source | First name of sampler or witnessed by | Victor |
| Last name of sampler or witnessed by | Wami | Title of sampler | ASR |
| Telephone number of sampler | Laboratory sample identification | 1003-13 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Cemex | |
| Transportation Laboratory (TL) Number | 13 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1610836 |
|---|---|---|---|
| The truck number from where the sample was collected | load 4 | The batch plant ticket number from where the sample was collected | 10067295 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Chute | Where the material sample would have been placed if not sampled | monte vista ave bent cap intermediate and end diaphrams |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2020-11-13-9
DIME Test ID: 2020-11-13-9-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-12-28
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: JOSE GUZMAN
Date of test: 11/27/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 142165 lb
Maximum load on cylinder 2: 137165 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 5044.9 psi
Compressive strength of cylinder 2: 4867.5 psi
Compressive strength (to nearest 10 psi): 4960 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/28/2020 ✔