Summary for Test 2020-02-27-26-6
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
---|---|
DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
Award Date | 05/01/2019 |
Closeout Date | 02/22/2024 |
Work Description | Not set |
Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 02/27/2020 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/28/2020 |
Sample type | Verification | A brief description of the sample | 3/4" HMA - A, LL (Rich Bottom) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Walt | Last name of sampler or witnessed by | Wylie (Witness) |
Title of sampler | Teichert Personnel | Telephone number of sampler | |
Laboratory sample identification | JMF20-003 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Perkins - Continuous Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-02-27-26
DIME Test ID: 2020-02-27-26-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-12-24
Test Results
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 03/25/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.49 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 3.53 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters): JMF20-003
Test was verified on 12/24/2020 ✔