Summary for Test 2020-02-12-45-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date02/12/2020 Sample Unique Key45
Date that the sample was received by the laboratory/organization performing the testing02/13/2020 Sample typeVerification
A brief description of the sample3/4" HMA - A, LL (Intermidiate) The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byWalt
Last name of sampler or witnessed byWylie (WITNESS) Title of samplerTeichert Personnel
Telephone number of sampler Laboratory sample identificationJMF20-001
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Perkins - Continuous Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-02-12-45
DIME Test ID: 2020-02-12-45-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2020-12-22

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 03/16/2020
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated

142 psi

169 psi

84
General comments (publicly viewable) (Max 1000 characters): JMF20-001. Test date estimated.

Test was verified on 12/22/2020