Summary for Test 2020-11-30-16-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215364 DEA: 07333204 EFIS: 0716000301 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-.8/.8 |
Award Date | 09/08/2021 |
Closeout Date | 03/01/2023 |
Work Description | INSTALL SOLAR PV POWERED LIGHTING SYSTEM. |
Location Description | IN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA. |
QA Service Level | 1 (Verified on 07/12/2021) |
Sample Information
Sample Taken Date | 11/30/2020 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2020 |
Sample type | Per Request | A brief description of the sample | soil |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Adam | Last name of sampler or witnessed by | Avakian |
Title of sampler | Geotech Engineer | Telephone number of sampler | 9162037625 |
Laboratory sample identification | CR20200558 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C002434 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 06-KER-005 1.12 PM | |
Structure name | Solar Panel Project |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | HA-20-002 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Corrosion testing | A detailed description of where the material sample was collected | 0-2 feet depth |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-11-30-16
DIME Test ID: 2020-11-30-16-1
Testing Lab: WSP Environment & Infrastructure, Inc.
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-22
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 12/16/2020
Minimum soil resistance of the lab measurement: 1850 Ohms
Soil sample temperature: 19.4 C
Soil box constant: 1
pH of soil: 7.44
Minimum soil resistance corrected to 15.5: 2030 Ohm-cm
Minimum soil resistivity at 15.5: 2030 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/22/2020 ✔