Summary for Test 2020-11-30-15-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 215364
DEA: 07333204
EFIS: 0716000301
DIST-CO-RTE-PM07-LA-5-.8/.8
Award Date09/08/2021
Closeout Date03/01/2023
Work DescriptionINSTALL SOLAR PV POWERED LIGHTING SYSTEM.
Location DescriptionIN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date11/30/2020 Sample Unique Key15
Date that the sample was received by the laboratory/organization performing the testing12/04/2020 Sample typePer Request
A brief description of the samplesoil The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byAdam
Last name of sampler or witnessed byAvakian Title of samplerGeotech Engineer
Telephone number of sampler9162037625 Laboratory sample identificationCR20200557
Linked DIME Sample ID The fabricator/manufacturer/facility nameCaltrans
Transportation Laboratory (TL) NumberC002433 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier06-KER-005 0.68 PM Structure nameSolar Panel Project
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleHA-20-001
The fabricator/manufacturer designation for the sampleCorrosion testing A detailed description of where the material sample was collected3.5 - 6 feet depth
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2020-11-30-15
DIME Test ID: 2020-11-30-15-1
Testing Lab: WSP USA - San Diego
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-22

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 12/16/2020
Minimum soil resistance of the lab measurement: 2200 Ohms
Soil sample temperature: 19.6 C
Soil box constant: 1
pH of soil: 7.96
Minimum soil resistance corrected to 15.5: 2426 Ohm-cm
Minimum soil resistivity at 15.5: 2426 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/22/2020 ✔