Summary for Test 2020-12-09-13-1
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/09/2020 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/15/2020 | Sample type | Quality Assurance |
| A brief description of the sample | Ductile Iron Casting | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Michelle |
| Last name of sampler or witnessed by | Haughey | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SDI Farrar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | K030 K040 K170 |
|---|---|---|---|
| Part Number (s) | 27 6 PC BP | Material Specification | A536 |
| Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
| Prestressing Manufacturer | SDI |
Test Details
DIME Sample ID: 2020-12-09-13
DIME Test ID: 2020-12-09-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-12-16
Test Results
Number of Samples: 3
Input Type: Calculated
Tester's full name: fsaylor
Date of test: 12/15/2020
UTM: 67kip
Temperature: 72 F
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | K030 | 0.503 | 0.19871 | 62889 | 107512 | 9.1 | fsaylor | |
| 2 | K040 | 0.503 | 0.19871 | 63353 | 110448 | 9.5 | fsaylor | |
| 3 | K170 | 0.503 | 0.19871 | 63735 | 111938 | 9.5 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 12/16/2020 ✔