Summary for Test 2020-12-11-1-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 213856
DEA: 112888U4
EFIS: 1118000199
DIST-CO-RTE-PM11-SD-11,125,905-Various
Award Date05/09/2019
Closeout Date09/14/2023
Work DescriptionCONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date12/11/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing12/15/2020 Sample typeRetest
A brief description of the sampleNo 11 Headed Reinforcement The quantity of what the sample constitutes1 Lot of 74 Headed Bars
From where was the sample collectedFabricator First name of sampler or witnessed bySteve
Last name of sampler or witnessed byHall Title of samplerCT METS QA INSPECTOR
Telephone number of sampler6466327821 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameIntegrity Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL134-291-20
Structure unique identifier Structure nameAlta Road Overcrossing
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingRetest
Rebar Heat Number(s)65029069 Head Manufacturer Lot Number(s)A201362
Rebar Size#11 Headed Bar Model NameButtonhead BNX
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerGerdau
Head ManufacturerBar Splice Head FabricatorIntegrity Rebar
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2020-12-11-1
DIME Test ID: 2020-12-11-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-12-16

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 12/15/2020
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
111.5615133397009Ok neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 12/16/2020 ✔