Summary for Test 2020-11-10-13-1

Test performed: ASTM A931-0810

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/10/2020 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing12/14/2020 Sample typeQuality Assurance
A brief description of the sampleWire Choker The quantity of what the sample constitutes2
From where was the sample collectedSource First name of sampler or witnessed bylaura
Last name of sampler or witnessed byMellizo Title of sampler
Telephone number of sampler858 518 8270 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDistrict 11 Maitenance
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM10 - Wire Rope Choker Reel Number650105
Painter Name or IDBarreva Sigala Material SpecificationASTM A931
Size5/16 in Wire Manufacturer
Material Collected to TestOperator

Test Details

DIME Sample ID: 2020-11-10-13
DIME Test ID: 2020-11-10-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Test Release Date: 2020-12-15

Test Results


Input Type: Calculated
Tester's full name:
Date of test: 12/15/2020
Temperature: 72 F
UTM: 67kip
Specimen Identification: Wire Rope
Peak Load: 10987.8
Operator: Barreva
Location of Failure: Below Crimp
General comments (publicly viewable) (Max 1000 characters): Wire Rope
Test Graph
Source: Bluehill Data Point File
Test graph for 2020-11-10-13-1

Test was verified on 12/15/2020