Summary for Test 2015-04-21-2-2
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 209453 DEA: 080J8504 EFIS: 0800000324 |
---|---|
DIST-CO-RTE-PM | 08-SBD-138-R24.1 |
Award Date | 07/01/2014 |
Closeout Date | 07/05/2017 |
Work Description | REPLACE EXISTING BRIDGE. |
Location Description | SAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT HORSETHIEF CREEK BRDIGE |
QA Service Level | 1 (Verified on 04/16/2014) |
Sample Information
Sample Taken Date | 04/21/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | MANDEEP | Last name of sampler or witnessed by | KINGRA |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 901 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 2960 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Horsethief Bridge |
Material Information
Material Type | Concrete | The concrete mix design number | SIT172A |
---|---|---|---|
The truck number from where the sample was collected | 0192 | The batch plant ticket number from where the sample was collected | 821540 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Bent Cap at Bent 3 | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-04-21-2
DIME Test ID: 2015-04-21-2-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-04-30
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/01/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 110100 lb
Maximum load on cylinder 2: 109900 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 10 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3880.9 psi
Compressive strength of cylinder 2: 3873.8 psi
Compressive strength (to nearest 10 psi): 3880 psi
General comments (publicly viewable) (Max 1000 characters): CORRECT DATE OF POUR IS APRIL 20 2015
Test was verified on 4/30/2015 ✔