Summary for Test 2026-06-30-13-6
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075 |
|---|---|
| DIST-CO-RTE-PM | 03-SOL,YOL-50,80,113-Var |
| Award Date | 09/27/2024 |
| Closeout Date | Not set |
| Work Description | HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS. |
| Location Description | SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/17/2024) |
Sample Information
| Sample Taken Date | 06/30/2026 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA 25% RAP |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Luis | Last name of sampler or witnessed by | Magana |
| Title of sampler | QA Tech | Telephone number of sampler | 2092250104 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Desilva Gates-Marysville | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 4 |
| Sublot number | 11 | HMA Mix Number | MD 6736 |
| Binder content (%) | 0.0 | Virgin binder PG | PG 58-22 |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | 25 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-30-13
DIME Test ID: 2026-06-30-13-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: KHUE YANG
Date of test: 07/02/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4043.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6211.6 g
Mass of HMA Sample prior to ignition: 2168.4 g
Mass Loss: 122.9 g
Mass of aggregate remaining after ignition: 2045.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.68 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.99 %
General comments (publicly viewable) (Max 1000 characters):