Summary for Test 2024-12-09-69-3
Test performed: CTM 214-August 2010Project Information
| Project Identifiers | Project ID: 994469 DEA: 044J89U4 EFIS: 0419000140 COOP: 042806 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL-82-18.2/26.4 |
| Award Date | 08/17/2023 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC, RHMA, SLAB REPL, CURB RAMPS, AND MOD ELECT SYSTEMS. |
| Location Description | SANTA CLARA COUNTY AT VARIOUS LOCATIONS FROM KNICKERBOCKER DRIVE IN SUNNYVALE TO SAN MATEO COUNTY LINE IN PALO ALTO |
| QA Service Level | 1 (Verified on 05/09/2023) |
Sample Information
| Sample Taken Date | 12/09/2024 | Sample Unique Key | 69 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/04/2025 |
| Sample type | Annual Source Testing | A brief description of the sample | 3/8" Pea Gravel |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Charles | Last name of sampler or witnessed by | Poolis |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | 1080 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan - Los Banos TRP | Transportation Laboratory (TL) Number | C317-120924-2 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-24-0009 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-12-09-69
DIME Test ID: 2024-12-09-69-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test results have not been published/verified or have not been released yet by the testing organization.
To make the test results available to others outside of your organization, a DIME organization manager for your organization must verify the results.