Summary for Test 2025-06-10-5-3

Test performed: CTM 342-August 2012

Project Information

Project IdentifiersProject ID: 1000409
DEA: 051S1604
EFIS: 0524000176
DIST-CO-RTE-PM05-MON-1-60
Award Date06/14/2024
Closeout Date08/21/2026
Work DescriptionRocky Creek Slip Out Permanent Restoration Project
Location DescriptionNot set
QA Service Level1 (Verified on 06/26/2024)

Sample Information

Sample Taken Date06/10/2025 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing06/10/2025 Sample typeAcceptance
A brief description of the sampleSkid Testing Request The quantity of what the sample constitutesMultiple Lanes
From where was the sample collectedJob Site First name of sampler or witnessed byNeil
Last name of sampler or witnessed byWeller Title of samplerBCE
Telephone number of sampler8054712109 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGordon Ball Construction
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier44-0302 Structure nameRocky Creek Viaduct
Bid ItemNot set

Material Information

Material TypeRoadway/Bridge Surface Pavement Surface TypePCC (Portland Cement Concrete)
Type of Traffic Control ProvidedStationary Lane Closure DIST-CO-RTE05-MON-001
Direction of TravelNorth Post Mile60.00
Lanes to be TestedShoulder,Lane #1,Lane #2 Station

Test Details

DIME Sample ID: 2025-06-10-5
DIME Test ID: 2025-06-10-5-3
Testing Lab: CT HQ - FFS - Skid Testing
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Test Release Date: 2025-06-27

Test Results


Pavement or Bridge Deck?: Bridge Deck
Input Type: Measured
Tester's full name: HARISH THAKUR
Date of test: 06/27/2025
Air Temperature: 50 F
Tire Pressure: 24 psi
Equipment PST #: 10007/1008
Is Calibration within ± values: Yes
Weather: COOL
Direction/Lane #: NB: Northbound Direction of Travel
Edge used to measure reference distance: BEGIN BRIDGE
Edge used to measure position: LEFT OF WALL
Reference Distance 1: 30 ft
Reference Distance 2: 33 ft
Reference Distance 3: 36 ft
Direction and Lane # for Stationing 1: no data
Direction and Lane # for Stationing 2: no data
Direction and Lane # for Stationing 3: no data
Position for Stationing 1: 4 ft
Position for Stationing 2: 4 ft
Position for Stationing 3: 4 ft
Percent Grade for 1st Stationing: -3.0 %
Percent Grade for 2nd Stationing: -3.0 %
Percent Grade for 3rd Stationing: -3.0 %
Corrected Coefficients of Friction for Stationing 1: 0.44
Corrected Coefficients of Friction for Stationing 2: 0.44
Corrected Coefficients of Friction for Stationing 3: 0.44
Average Coefficient of Friction: 0.44
General comments (publicly viewable) (Max 1000 characters): ROCKY CREEK BRIDGE . VISUALLY INSPECTED ENTIRE BRIDGE WHICH HAD POLYESTER PLACED ON IT AS THAT IS THE SECTION OF THE BRIDGE THAT WAS REQUESTED FOR TESTING AND ALL LOOKED TO BE UNIFORMED IN BOTH DIRECTIONS APPROACH SLAB-.44-.44-.44 = .44AVG DEPARTURE SLAB .44-.44-.44=44AVG

Test was verified on 6/27/2025 ✔