Summary for Test 2015-06-18-2-3
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 208642 DEA: 07252004 EFIS: 0712000074 |
---|---|
DIST-CO-RTE-PM | 07-LA-405-39.4/48.6 |
Award Date | 06/28/2013 |
Closeout Date | 08/25/2016 |
Work Description | REPLACE CONC PAVEMENT WITH PRECAST PRESTRESSED CONC PAVEMENT. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM ROUTE 405/101 SEPARATION TO ROUTE 405/5 SEPARATION |
QA Service Level | 1 (Verified on 08/13/2013) |
Sample Information
Sample Taken Date | 06/18/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/22/2015 |
Sample type | Quality Control | A brief description of the sample | Concrete Cylinder 6 x 12 |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | George | Last name of sampler or witnessed by | Boules |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 910-01 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Associate Ready mixed Concrete | Transportation Laboratory (TL) Number | S4 S3 S2 S1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Austin Vault footing pour |
Material Information
Material Type | Concrete | The concrete mix design number | 557237 |
---|---|---|---|
The truck number from where the sample was collected | 488 | The batch plant ticket number from where the sample was collected | 5184684 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Associate Ready mixed Concrete |
A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-06-18-2
DIME Test ID: 2015-06-18-2-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-03
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/03/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 112620 lb
Maximum load on cylinder 2: 106030 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 14 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3969.7 psi
Compressive strength of cylinder 2: 3737.4 psi
Compressive strength (to nearest 10 psi): 3850 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/3/2015 ✔