Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-12-30-9
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214702 DEA: 030F2864 EFIS: 0320000123 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-7.92 / 8.4 |
Award Date | 06/24/2020 |
Closeout Date | 11/28/2023 |
Work Description | Remove and replace Consumnes River and Consumnes River Overflow bridge |
Location Description | Sacramento County |
QA Service Level | 1 (Verified on 04/20/2020) |
Sample Information
Sample Taken Date | 12/30/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/07/2021 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 61 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | ||
Group Number | 10961 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0569320-2, S0569120-2, S0569720-3, S0514120-2, S0525620, S0568320, S0218590, S0216056, S0218045, S0559420-2, S0514420-2, S0513920-2, S0514320-2 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Submitted Tests
Go to page:
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-12-30-9-1 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-2 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-3 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-4 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-5 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-6 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-7 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-8 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-9 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-10 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-11 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-12 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-13 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-14 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-15 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-16 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-17 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-18 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-19 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-20 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-21 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-22 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-23 ASTM A416-15 (Verified)
DIME Test ID: 2020-12-30-9-24 ASTM A416-15 (Verified)