Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2018-10-19-5
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 10/19/2018 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/26/2018 |
Sample type | Independent Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | IQA FIELD INSPECTOR | Telephone number of sampler | 510-693-3545 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SFI | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-062-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412933 |
---|---|---|---|
Heat Number(s) | 10524480 | Nut Mfg. Lot Number(s) | TN731 |
Washer Mfg. Lot Number(s) | D4996Z | Bolt Specification | A325 |
Bolt Length(s) | 11" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 070318-1AG |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Submitted Tests
Go to page:
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2018-10-19-5-1 ASTM F606-14a (Verified)
DIME Test ID: 2018-10-19-5-2 ASTM F606-14a (Verified)
DIME Test ID: 2018-10-19-5-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-19-5-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-19-5-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-19-5-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-19-5-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-19-5-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2018-10-19-5-9 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-10 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-11 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-12 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-13 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-14 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-15 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-16 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-17 ASTM B499-14 (Verified)
DIME Test ID: 2018-10-19-5-18 ASTM E18-15 (Verified)
DIME Test ID: 2018-10-19-5-19 ASTM E18-15 (Verified)