Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-05-31-3
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 212468 DEA: 113A0534 EFIS: 1117000127 |
---|---|
DIST-CO-RTE-PM | 11-SD-75- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 05/25/2017) |
Sample Information
Sample Taken Date | 05/31/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/02/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554, A449 |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Universal Industrial Sales, Wrought Washer Mfg Inc Platte Decker | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L0203517 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | PL16106308 | Nut Mfg. Lot Number(s) | NR791, 16-41-009 |
Washer Mfg. Lot Number(s) | 230608 | Bolt Specification | F1554-55, A449 |
Bolt Length(s) | 3", 12" | Nut Specification | A5463 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1.5", 1" | Bolt Mfg. Lot Number | 166707 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Go to page:
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-05-31-3-1 ASTM F606-14 (Verified)
DIME Test ID: 2017-05-31-3-6 ASTM F606-14a (Verified)
DIME Test ID: 2017-05-31-3-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-14 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-05-31-3-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-21 ASTM E18-15 (Verified)
DIME Test ID: 2017-05-31-3-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-05-31-3-23 ASTM B499-14 (Verified)