Sample Record

Owner Lab

  • CT D04 - Concord Field Laboratory

DIME Sample ID 2024-09-05-58

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994378
DEA: 040K6304
EFIS: 0416000111
DIST-CO-RTE-PM04-NAP-29-16.4/19.0
Award Date06/27/2023
Closeout DateNot set
Work DescriptionBRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING.
Location DescriptionNAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG
QA Service Level1 (Verified on 10/27/2022)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2024
Sample typeQuality Assurance A brief description of the samplePCC Aggregates
The quantity of what the sample constitutes45 CY From where was the sample collectedSupplier
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byValdez
Title of samplerLab Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNorthgate Ready Mix Sonoma Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-49-0043
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedFrom Stockpiles at the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number3B6386 Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-09-05-58-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesNicholas Hall, CT D04 - Concord Field Laboratory09/05/202409/12/2024
Yes
09/12/2024Public - Test Data Visible
2024-09-05-58-2CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesAnthony Valdez, CT D04 - Concord Field Laboratory09/05/202409/12/2024
Yes
09/12/2024Out of spec on 1/2, #4 and #8Public - Test Data Visible
2024-09-05-58-3CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesAnthony Valdez, CT D04 - Concord Field Laboratory09/05/202409/12/2024
Yes
09/12/2024Public - Test Data Visible
2024-09-05-58-4CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Anthony Valdez, CT D04 - Concord Field Laboratory09/05/202409/12/2024
Yes
09/12/2024For 1 X #4 MaterialPublic - Test Data Visible
2024-09-05-58-5CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Anthony Valdez, CT D04 - Concord Field Laboratory09/05/202409/12/2024
Yes
09/12/2024For 3/8" MaterialPublic - Test Data Visible
2024-09-05-58-6CTM 217-June 2011: Method of Test for Sand EquivalentAnthony Valdez, CT D04 - Concord Field Laboratory09/05/202409/12/2024
Yes
09/12/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-09-05-58-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-09-05-58-2 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-09-05-58-3 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-09-05-58-4 CTM 227-December 2014 (Verified)
DIME Test ID: 2024-09-05-58-5 CTM 227-December 2014 (Verified)
DIME Test ID: 2024-09-05-58-6 CTM 217-June 2011 (Verified)