Sample Record

DIME Sample ID 2017-01-04-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211070
DEA: 080Q3004
EFIS: 0800020191
DIST-CO-RTE-PM08-SBD-138-R17.1/R19.2
Award Date04/18/2016
Closeout Date09/28/2020
Work DescriptionREALIGN SECTION OF STATE ROUTE 138
Location DescriptionNear Hesperia from 1.9 mi East of Route 15 to 0.1 mi West of Summit Post Office Road to realign sections of State Route 138
QA Service Level1 (Verified on 04/27/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date01/04/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/11/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byRussell
Last name of sampler or witnessed byLynch Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar Gerdau
Transportation Laboratory (TL) NumberC939550 Inspector Lot Number from the Transportation Laboratory (TL) FormL9600417
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)6502542002
Hoop Manufacturer Lot Number(s)9, 12 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-01-04-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/12/201701/12/2017
Yes
01/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-04-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/12/201701/12/2017
Yes
01/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-04-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/12/201701/12/2017
Yes
01/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-04-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/12/201701/12/2017
Yes
01/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-04-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/12/201701/12/2017
Yes
01/19/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-01-04-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/12/201701/12/2017
Yes
01/19/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-01-04-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-04-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-04-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-04-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-04-3-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-01-04-3-6 CTM 670-December 2013 (Verified)