Sample Record

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2024-09-07-2

Project Information

Project IdentifiersProject ID: 215445
DEA: 100X7504
EFIS: 1013000009
DIST-CO-RTE-PM10-ALP-4,88,89-var
Award Date03/18/2021
Closeout Date04/22/2025
Work DescriptionREPLACE BRIDGE RAIL, BARRIER SLAB AND GUARDRAIL.
Location DescriptionALPINE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 02/01/2021)

Sample Information

Sample Taken Date09/07/2024 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/07/2024
Sample typeQuality Assurance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes3 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed bySpencer Last name of sampler or witnessed byAdams
Title of samplerMREA Telephone number of sampler9165941991
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBridgeway Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier31-0022
Structure nameMarkleeville LOC 1 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number3701302428
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedunknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedFrom mixer Where the material sample would have been placed if not sampled
From Lot No.3701302428 Bag Lot No.3701302428

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-09-07-2-1ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory09/08/202409/08/2024
Yes
09/08/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-09-07-2-1 ASTM C39-21 (Verified)