Sample Record
Owner Lab
- Sequoia Consultants
DIME Sample ID 2024-06-27-124
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 994191 DEA: 081G8304 EFIS: 0816000079 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R100.8/R101.8 |
| Award Date | 02/07/2023 |
| Closeout Date | 08/29/2025 |
| Work Description | HMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW. |
| Location Description | SAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE |
| QA Service Level | 1 (Verified on 03/30/2023) |
Sample Information
| Sample Taken Date | 06/27/2024 | Sample Unique Key | 124 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/27/2024 |
| Sample type | Quality Control | A brief description of the sample | 1x4 concrete aggregates |
| The quantity of what the sample constitutes | 1 per batch | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Cynthia | Last name of sampler or witnessed by | Flores |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cemex - Bullhead City | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00-00-0000 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | stockpile or belt cut | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-06-27-124-1 CTM 226-July 2010 (Verified)
DIME Test ID: 2024-06-27-124-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2024-06-27-124-3 CTM 227-December 2014 (Verified)
DIME Test ID: 2024-06-27-124-4 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-06-27-124-5 CTM 202-November 2011 (Verified)