Sample Record
DIME Sample ID 2024-08-21-9
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 994816 DEA: 010E11U4 EFIS: 0123000069 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-1-31.1/31.6 |
| Award Date | 11/15/2023 |
| Closeout Date | Not set |
| Work Description | STRUCTURAL CONC BRIDGE, TEMP BRIDGE AND BAR REINFORCING STEEL. |
| Location Description | MENDOCINO COUNTY NEAR ELK FROM 0.2 MILE SOUTH OF ELK CREEK BRIDGE TO 0.2 MILE NORTH OF ELK CREEK BRIDGE |
| QA Service Level | 1 (Verified on 05/22/2023) |
Owner Lab
- CT HQ - QASI Sacramento Field Office
Sample Information
| Sample Taken Date | 08/21/2024 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/26/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 1-1/4"x30" F1554 Grade 105 Anchor Rod | The quantity of what the sample constitutes | 2 Anchor Rods |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Alvarez | Title of sampler | CALTRANS METS QA INSPECTOR |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | C & K Johnson Industries | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 20912690 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F1554 | |
| Bolt Length(s) | 30" | Nut Specification | A194 |
| Washer Specification | F436 | Finish | ASTM A153 - Hot Dip |
| Diameter/Size | 1-1/4" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-08-21-9-1 ASTM A370-20 (Verified)
DIME Test ID: 2024-08-21-9-2 ASTM A370-20 (Verified)
DIME Test ID: 2024-08-21-9-3 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-08-21-9-4 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-08-21-9-5 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-08-21-9-6 ASTM B499-09r21 (Verified)