Sample Record

DIME Sample ID 2024-07-13-15

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993387
DEA: 07323404
EFIS: 0716000064
DIST-CO-RTE-PM07-LA-5-R59.5/R67.9
Award Date02/25/2022
Closeout Date06/30/2026
Work DescriptionPLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING
QA Service Level1 (Verified on 12/06/2021)

Owner Lab

  • Alta Vista Solutions - Whittier

Sample Information

Sample Taken Date07/13/2024 Sample Unique Key15
Date that the sample was received by the laboratory/organization performing the testing07/13/2024 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes10 cubic yards
From where was the sample collectedJob Site First name of sampler or witnessed byManuel
Last name of sampler or witnessed byUy Title of sampler
Telephone number of sampler Laboratory sample identification24-1932-1933-1934-1935
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3 21 CTS 220
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTruck 9
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-07-13-15-2CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteManuel Uy, Alta Vista Solutions - Whittier08/15/202408/15/2024
Yes
08/15/2024Log # 24-1932Public - Test Data Visible
2024-07-13-15-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersAleksey Souglobov, Alta Vista Solutions - Whittier07/20/202408/15/2024
Yes
08/15/2024Log #'s 24/1933-1934-1935Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-07-13-15-2 CTM 557-June 2020 (Verified)
DIME Test ID: 2024-07-13-15-3 CTM 521-June 2020 (Verified)