Sample Record

DIME Sample ID 2024-06-23-41

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994966
DEA: 073255U4
EFIS: 0722000129
DIST-CO-RTE-PM07-LA-605-20.2/26
Award Date04/12/2023
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC
Location DescriptionLOS ANGELES COUNTY IN BALDWIN PARK AND IRWINDALE FROM ROUTE 10/605 SEPARATION TO 0.2 MILE NORTH OF ROUTE 210/605 SEPARATION
QA Service Level1 (Verified on 07/13/2023)

Owner Lab

  • Alta Vista Solutions - Whittier

Sample Information

Sample Taken Date06/23/2024 Sample Unique Key41
Date that the sample was received by the laboratory/organization performing the testing06/23/2024 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes10 cubic yards
From where was the sample collectedJob Site First name of sampler or witnessed byEdmond
Last name of sampler or witnessed byJabbour Title of sampler
Telephone number of sampler Laboratory sample identification24-1582-1583-1584-1585
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-30-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedLoad 1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-06-23-41-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMichael Magana, Alta Vista Solutions - Whittier06/30/202408/13/2024
Yes
08/13/2024Log #'s 24/1583-1584-1585Public - Test Data Visible
2024-06-23-41-2CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteEdmond Jabbour, Alta Vista Solutions - Whittier06/23/202408/13/2024
Yes
08/13/2024Log # 24-1582Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-06-23-41-1 CTM 521-June 2020 (Verified)