Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2016-12-15-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209950
DEA: 080N56U4
EFIS: 0813000176
DIST-CO-RTE-PM08-SBD-40-R94.7/R99.7
Award Date01/22/2015
Closeout Date09/17/2018
Work DescriptionBRIDGE REPLACEMENTS.
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE
QA Service Level1 (Verified on 04/29/2015)

Sample Information

Sample Taken Date12/15/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/19/2016
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byADLAI Last name of sampler or witnessed byEVANS
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification907-15 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameROBERTSONS Transportation Laboratory (TL) Number20161215
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierCLIPPER AND HALLER WASH BR
Structure namePIER CAPS 3 4 6 AND 7 AT CLIPPER

Material Information

Material TypeConcrete The concrete mix design numberRRM15028
The truck number from where the sample was collected1692 The batch plant ticket number from where the sample was collected1082093
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTRUCK Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-12-15-3-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory12/22/2016Matthew Clayton
Yes
12/22/2016
2016-12-15-3-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory01/12/2017Matthew Clayton
Yes
01/12/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-12-15-3-1 ASTM C39-17a (Verified)
DIME Test ID: 2016-12-15-3-2 ASTM C39-17a (Verified)