Sample Record

Owner Lab

  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2024-08-09-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995524
DEA: 021H3604
EFIS: 0216000040
DIST-CO-RTE-PM02-SIS-96-76.8/78.0
Award Date03/22/2024
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK
QA Service Level1 (Verified on 12/27/2023)

Sample Information

Sample Taken Date08/09/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2024
Sample typeQuality Assurance A brief description of the sampleHRC 500 510 Couplers
The quantity of what the sample constitutes8 rebar with Mechanical Couplers From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byAlvarez
Title of samplerQuality Assurance Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Tracy CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#14 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73130162, 73129190/Lots 1-2 Rebar Heat Number(s)3129862, 3129863
Rebar Size 2 Coupler Unique IDTF-17-01

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-08-09-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Ok Necking - UltimatePublic - Test Data Visible
2024-08-09-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Ok Necking - UltimatePublic - Test Data Visible
2024-08-09-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Ok Necking - UltimatePublic - Test Data Visible
2024-08-09-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Public - Test Data Visible
2024-08-09-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Ok Necking - UltimatePublic - Test Data Visible
2024-08-09-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Ok Necking - UltimatePublic - Test Data Visible
2024-08-09-1-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/29/202408/29/2024
Yes
08/29/2024Ok Necking - UltimatePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-08-09-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-09-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-09-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-09-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-09-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-09-1-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-09-1-7 CTM 670-December 2013 (Verified)