Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2024-08-02-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000409
DEA: 051S1604
EFIS: 0524000176
DIST-CO-RTE-PM05-MON-1-60
Award DateNot set
Closeout DateNot set
Work DescriptionRocky Creek Slip Out Permanent Restoration Project
Location DescriptionNot set
QA Service Level1 (Verified on 06/26/2024)

Sample Information

Sample Taken Date08/02/2024 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/05/2024
Sample typeQuality Assurance A brief description of the sample#8 x 4' diameter hoops
The quantity of what the sample constitutes384 From where was the sample collectedFabricator
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler9152961869
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-035-24 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)125424
Hoop Manufacturer Lot Number(s)1 and 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop4'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade - Oregon
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-08-02-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202408/07/2024
Yes
08/07/2024Ok NeckingPublic - Test Data Visible
2024-08-02-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202408/07/2024
Yes
08/07/2024Ok NeckingPublic - Test Data Visible
2024-08-02-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202408/07/2024
Yes
08/07/2024Ok NeckingPublic - Test Data Visible
2024-08-02-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202408/07/2024
Yes
08/07/2024Ok NeckingPublic - Test Data Visible
2024-08-02-2-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202408/07/2024
Yes
08/07/2024Ok NeckingPublic - Test Data Visible
2024-08-02-2-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/07/202408/07/2024
Yes
08/07/2024Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-08-02-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-02-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-02-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-02-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-02-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-08-02-2-6 CTM 670-December 2013 (Verified)