Sample Record

DIME Sample ID 2024-07-17-86

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994751
DEA: 010C5004
EFIS: 0112000292
DIST-CO-RTE-PM01-HUM-36-11.3/34.6
Award Date03/02/2023
Closeout DateNot set
Work DescriptionProject Name: Bridge Rail Replacement - 3 Bridges
Location DescriptionHely Creek, Little Larabee Creek and Butte Creek Bridge.
QA Service Level1 (Verified on 04/27/2023)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date07/17/2024 Sample Unique Key86
Date that the sample was received by the laboratory/organization performing the testing07/31/2024 Sample typeQuality Assurance
A brief description of the sampleBarlock couplers The quantity of what the sample constitutesNA
From where was the sample collectedJob Site First name of sampler or witnessed byR
Last name of sampler or witnessed byDuran Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameJob Site
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelD250 Bar Lock L-Series Type 2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000016129, 4000017378, a231787 Rebar Heat Number(s)3500032333, 3500032332
Rebar Size 2 Coupler Unique IDSL-17-06

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-07-17-86-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible
2024-07-17-86-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/31/2024
Yes
07/31/2024Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-07-17-86-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-17-86-8 CTM 670-December 2013 (Verified)