Sample Record
DIME Sample ID 2016-12-02-3
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-171.8/173.8 |
| Award Date | 11/04/2015 |
| Closeout Date | 08/21/2018 |
| Work Description | BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT. |
| Location Description | In SBD County |
| QA Service Level | 1 (Verified on 10/19/2015) |
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Information
| Sample Taken Date | 12/02/2016 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/07/2016 | Sample type | Quality Assurance |
| A brief description of the sample | A536 Ductile Iron | The quantity of what the sample constitutes | 2 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Debbie |
| Last name of sampler or witnessed by | Ozuna | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | DSI Dotson Iron |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 3276 |
|---|---|---|---|
| Part Number (s) | 68 19 216 248 | Material Specification | A536 |
| Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Dotson Iron Castings |
| Prestressing Manufacturer | DSI |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2016-12-02-3-1 ASTM A370-15 (Verified)