Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2024-07-18-48

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994346
DEA: 033F23U4
EFIS: 0322000243
DIST-CO-RTE-PM03-PLA-80-0.1/2.2,4.9/6.0
Award Date05/25/2023
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, PLACE CL2-AB, HMA, STRUCTURAL CONCRETE & RCP.
Location DescriptionPLACER COUNTY IN ROSEVILLE FROM 0.1 MILE WEST OF RIVERSIDE AVENUE OVERCROSSING TO 0.3 MILE EAST OF DOUGLAS BOULEVARD OVERCROSSING AND IN ROCKLIN FROM 1.1 MILE WEST OF ROCKLIN ROAD UNDERCROSSING TO ROCKLIN ROAD UNDERCROSSING
QA Service Level1 (Verified on 11/09/2022)

Sample Information

Sample Taken Date07/18/2024 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/18/2024
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes1 From where was the sample collectedJob Site
First name of sampler or witnessed byAsia Last name of sampler or witnessed byAl Maliki
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJob Site Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerEaton Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelLenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A233654 Rebar Heat Number(s)4137982
Rebar Size 2 Coupler Unique IDST-17-01

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-07-18-48-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/23/2024
Yes
07/24/2024Service SplicePublic - Test Data Visible
2024-07-18-48-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/23/2024
Yes
07/24/2024Service SplicePublic - Test Data Visible
2024-07-18-48-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/22/202407/23/2024
Yes
07/24/2024Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-07-18-48-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-07-18-48-2 CTM 670-December 2013 (Verified)