Sample Record

Owner Lab

  • CT D06 - Millbrook Field Laboratory

DIME Sample ID 2024-07-12-44

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000114
DEA: 060W8204
EFIS: 0617000304
DIST-CO-RTE-PM06-KIN-41-28.4/R40.1
Award Date05/22/2024
Closeout DateNot set
Work DescriptionCOLD PLANE WITH HOT MIX ASPHALT (TYPE A) AND RHMA-G.
Location DescriptionKINGS COUNTY AT AND NEAR STRATFORD FROM NEVADA AVENUE TO ROUTE 41/198 SEPARATION
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date07/12/2024 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2024
Sample typeAcceptance A brief description of the samplePPC Cylinders
The quantity of what the sample constitutes300 From where was the sample collectedJob Site
First name of sampler or witnessed byMartin Last name of sampler or witnessed byGarcia
Title of samplerStructure Representative Telephone number of sampler5592469430
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameOutback Materials, Fresno Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier45-0014
Structure nameEmpire No. 2 Canal Bridge

Material Information

Material TypeConcrete The concrete mix design number72T1G36
The truck number from where the sample was collected3 The batch plant ticket number from where the sample was collected163943
Concrete batch plantOutback Materials The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledSB Arrival and Departure Approach Slabs
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-07-12-44-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersGurjeet Litt, CT D06 - Millbrook Field Laboratory07/19/2024Gurjeet Litt
Yes
07/24/2024
2024-07-12-44-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersGurjeet Litt, CT D06 - Millbrook Field Laboratory07/30/2024Gurjeet Litt
Yes
07/30/2024
2024-07-12-44-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersGurjeet Litt, CT D06 - Millbrook Field Laboratory08/09/2024Gurjeet Litt
Yes
08/09/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-07-12-44-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-07-12-44-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-07-12-44-3 CTM 521-June 2020 (Verified)