Sample Record

Owner Lab

  • Sequoia Consultants

DIME Sample ID 2024-07-09-54

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993815
DEA: 081C0814
EFIS: 0816000086
DIST-CO-RTE-PM08-RIV-10-R60.7/R74.3
Award Date03/28/2022
Closeout DateNot set
Work DescriptionI-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location DescriptionCoachella
QA Service Level1 (Verified on 05/03/2022)

Sample Information

Sample Taken Date07/09/2024 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/09/2024
Sample typeQuality Control A brief description of the sample1x4 concrete aggregates
The quantity of what the sample constitutes1 per batch From where was the sample collectedSupplier
First name of sampler or witnessed byDeown Last name of sampler or witnessed byMalone
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHi-Grade - Indio Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0030
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedstockpile or belt cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-07-09-54-1CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven DryingJonathan Casanova, Sequoia Consultants07/11/2024Cassidy Pham
Yes
07/12/2024
2024-07-09-54-2CTM 217-June 2011: Method of Test for Sand EquivalentJonathan Casanova, Sequoia Consultants07/11/2024Cassidy Pham
Yes
07/12/2024
2024-07-09-54-3CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Jonathan Casanova, Sequoia Consultants07/11/2024Cassidy Pham
Yes
07/12/2024
2024-07-09-54-4CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJonathan Casanova, Sequoia Consultants07/11/2024Cassidy Pham
Yes
07/12/2024
2024-07-09-54-5CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJonathan Casanova, Sequoia Consultants07/11/2024Cassidy Pham
Yes
07/12/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-07-09-54-1 CTM 226-July 2010 (Verified)
DIME Test ID: 2024-07-09-54-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2024-07-09-54-3 CTM 227-December 2014 (Verified)
DIME Test ID: 2024-07-09-54-4 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-07-09-54-5 CTM 202-November 2011 (Verified)