Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2024-06-03-93

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215348
DEA: 060U4204
EFIS: 0616000004
DIST-CO-RTE-PM06-FRE-99-R4.9/11.6
Award Date02/25/2021
Closeout DateNot set
Work DescriptionCONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location DescriptionFRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
QA Service Level1 (Verified on 12/07/2020)

Sample Information

Sample Taken Date06/03/2024 Sample Unique Key93
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/04/2024
Sample typeQuality Control A brief description of the sample4X8 Concrete Cylinders
The quantity of what the sample constitutes5 From where was the sample collectedJob Site
First name of sampler or witnessed byAl Last name of sampler or witnessed byPineda
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationMix G3-22-BAR-318, Set 1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSecurity Paving Company Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name

Material Information

Material TypeConcrete The concrete mix design numberG3-22-BAR-318
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedBarrier Wall STA 93+80 Where the material sample would have been placed if not sampledUnknown
From Lot No.1 Bag Lot No.1

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-06-03-93-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMichael Kaus, G3 Quality, Incorporated - Cerritos06/11/2024Ricky Pham
Yes
07/10/2024
2024-06-03-93-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersDavid Silva, G3 Quality, Incorporated - Cerritos07/02/2024Ricky Pham
Yes
07/10/2024
2024-06-03-93-3CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteAl Pineda, G3 Quality, Incorporated - Cerritos06/03/2024Ricky Pham
Yes
07/10/2024
2024-06-03-93-4CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteAl Pineda, G3 Quality, Incorporated - Cerritos06/03/2024Ricky Pham
Yes
07/10/2024
2024-06-03-93-5CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodAl Pineda, G3 Quality, Incorporated - Cerritos06/03/2024Ricky Pham
Yes
07/10/2024
2024-06-03-93-6CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteAl Pineda, G3 Quality, Incorporated - Cerritos06/03/2024Ricky Pham
Yes
07/10/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-06-03-93-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-06-03-93-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-06-03-93-3 CTM 557-June 2020 (Verified)
DIME Test ID: 2024-06-03-93-4 CTM 518-June 2010 (Verified)
DIME Test ID: 2024-06-03-93-5 CTM 504-June 2010 (Verified)
DIME Test ID: 2024-06-03-93-6 CTM 533-June 2010 (Verified)