Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2024-06-27-2
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 994535 DEA: 010H8404 EFIS: 0118000117 |
---|---|
DIST-CO-RTE-PM | 01-LAK-20-2.0/2.8 |
Award Date | 07/21/2023 |
Closeout Date | Not set |
Work Description | RDWY EXC, PLACE HMA-A & RHMA, CONST SOLDIER PILE & RETAINING WALLS. |
Location Description | LAKE COUNTY ABOUT 6 MILES WEST OF UPPER LAKE FROM 0.6 MILE WEST OF IRVINE AVENUE TO 0.1 MILE EAST OF MID LAKE ROAD |
QA Service Level | 1 (Verified on 04/25/2023) |
Sample Information
Sample Taken Date | 06/27/2024 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/28/2024 |
Sample type | Quality Assurance | A brief description of the sample | #9 GR 80 hot rolled threaded bar |
The quantity of what the sample constitutes | 2252 pcs | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Subramony | Last name of sampler or witnessed by | Krishnamoorthy |
Title of sampler | Telephone number of sampler | 9512014921 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor Skyline | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 80 |
Threaded Bar Type | Rebar Size | #9 | |
Nut Specification for Threaded Bar | ASTM A576 | System Manufacturer | Nucor Skyline |
Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
Coating Standards | Uncoated | Bar Heat Number(s) | 5393880,5395823 |
Nut Heat Number(s) | 5991, 6349 | Bar Lot Number | |
Nut Lot Number | Coupler Heat Number(s) | ||
Coupler Grade |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-06-27-2-11 ASTM A615-20 (Verified)
DIME Test ID: 2024-06-27-2-12 ASTM A615-20 (Verified)
DIME Test ID: 2024-06-27-2-13 ASTM A615-20 (Verified)
DIME Test ID: 2024-06-27-2-14 ASTM A615-20 (Verified)