Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2024-06-27-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 994535 DEA: 010H8404 EFIS: 0118000117 |
|---|---|
| DIST-CO-RTE-PM | 01-LAK-20-2.0/2.8 |
| Award Date | 07/21/2023 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, PLACE HMA-A & RHMA, CONST SOLDIER PILE & RETAINING WALLS. |
| Location Description | LAKE COUNTY ABOUT 6 MILES WEST OF UPPER LAKE FROM 0.6 MILE WEST OF IRVINE AVENUE TO 0.1 MILE EAST OF MID LAKE ROAD |
| QA Service Level | 1 (Verified on 04/25/2023) |
Sample Information
| Sample Taken Date | 06/27/2024 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/28/2024 |
| Sample type | Quality Assurance | A brief description of the sample | #9 GR 80 hot rolled threaded bar |
| The quantity of what the sample constitutes | 2252 pcs | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Subramony | Last name of sampler or witnessed by | Krishnamoorthy |
| Title of sampler | Telephone number of sampler | 9512014921 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor Skyline | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 80 |
| Threaded Bar Type | Rebar Size | #9 | |
| Nut Specification for Threaded Bar | ASTM A576 | System Manufacturer | Nucor Skyline |
| Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
| Coating Standards | Uncoated | Bar Heat Number(s) | 5393880,5395823 |
| Nut Heat Number(s) | 5991, 6349 | Bar Lot Number | |
| Nut Lot Number | Coupler Heat Number(s) | ||
| Coupler Grade |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-06-27-2-11 ASTM A615-20 (Verified)
DIME Test ID: 2024-06-27-2-12 ASTM A615-20 (Verified)
DIME Test ID: 2024-06-27-2-13 ASTM A615-20 (Verified)
DIME Test ID: 2024-06-27-2-14 ASTM A615-20 (Verified)