Sample Record
Owner Lab
- CT D02 - Redding Northern Regional Laboratory
DIME Sample ID 2024-06-10-99
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 995054 DEA: 024H0204 EFIS: 0218000069 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-20.0/39.7 |
Award Date | 10/23/2023 |
Closeout Date | Not set |
Work Description | PLACE RHMA AND HMA, CORRECT SEGMENTS, AND REPLACE AC SURFACING. |
Location Description | TEHAMA COUNTY NEAR RED BLUFF FROM 0.8 MILE EAST OF SALT CREEK BRIDGE TO BAKER ROAD |
QA Service Level | 1 (Verified on 08/14/2023) |
Sample Information
Sample Taken Date | 06/10/2024 | Sample Unique Key | 99 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/10/2024 |
Sample type | Acceptance | A brief description of the sample | 2 bags of Shoulder Backing |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D79575 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis – Crystal Creek Aggregates (Redding, CA) | Transportation Laboratory (TL) Number | 876862 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0021 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-06-10-99-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-06-10-99-3 CTM 212-May 2010 (Verified)
DIME Test ID: 2024-06-10-99-4 CTM 217-June 2011 (Verified)
DIME Test ID: 2024-06-10-99-5 CTM 229-June 2011 (Verified)
DIME Test ID: 2024-06-10-99-6 CTM 205-December 2010 (Verified)
DIME Test ID: 2024-06-10-99-7 CTM 205-December 2010 (Verified)