Sample Record
Owner Lab
- CT D06 - Bakersfield Field Laboratory
DIME Sample ID 2024-06-17-82
Project Information
Project Identifiers | Project ID: 995217 DEA: 061F6904 EFIS: 0623000144 |
---|---|
DIST-CO-RTE-PM | 06-TUL-190-38/57, 39/47, 32/57 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Emergency Landslide Repair. Roadway / Slope / Culvert repairs. |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/13/2023) |
Sample Information
Sample Taken Date | 06/17/2024 | Sample Unique Key | 82 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/18/2024 |
Sample type | Acceptance | A brief description of the sample | PCC cylinders retaining wall |
The quantity of what the sample constitutes | Unknown Quantity | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Angelica | Last name of sampler or witnessed by | Zarate |
Title of sampler | STRUCTURAL INSPECTOR | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Collected at jobsite | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 185811 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Unknown | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-06-17-82-1 ASTM C39-17a (Verified)
File Name | Extension | Date Uploaded | Test ID | Actions |
---|---|---|---|---|
06-1F6904_37000_240617_07D | 06/24/2024 | 2024-06-17-82-1 | Info |
DIME Test ID: 2024-06-17-82-2 CTM 521-June 2020 (Verified)
File Name | Extension | Date Uploaded | Test ID | Actions |
---|---|---|---|---|
06-1F6904_37000_240617_28D | 07/15/2024 | 2024-06-17-82-2 | Info |
DIME Test ID: 2024-06-17-82-3 CTM 521-June 2012 (Verified)