Sample Record

Owner Labs

  • CT D03 - Olivehurst Northern Regional Laboratory
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2024-06-10-63

Project Information

Project IdentifiersProject ID: 993905
DEA: 034H5814
EFIS: 0320000240
DIST-CO-RTE-PM03-SAC-5-27.6/29.5,30.4/34.3
Award Date02/28/2023
Closeout Date06/02/2025
Work DescriptionROADWAY EXCAVATION, PLACE CL2 AB, HMA & RHMA, & MODIFY RAMP METERS.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR SACRAMENTO FROM 0.5 MILES SOUTH OF ARENA BOULEVARD OVERCROSSING TO 0.4 MILES SOUTH OF 99/5 INTERCHANGE AND FROM 0.5 MILES NORTH OF THE 99/5 INTERCHANGE TO 0.4 MILE SOUTH OF THE YOLO COUNTY LINE
QA Service Level1 (Verified on 06/27/2022)

Sample Information

Sample Taken Date06/10/2024 Sample Unique Key63
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/10/2024
Sample typeQuality Assurance A brief description of the sample6 4x8 Cylinders
The quantity of what the sample constitutes6 4x8 FIELD CURE concrete cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byPhillip Last name of sampler or witnessed byAsher
Title of samplerAssistant Structure Representative Telephone number of sampler916-768-8293
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex - West Sacramento Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameASN-4 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1626827
The truck number from where the sample was collected10069091 The batch plant ticket number from where the sample was collected42666418
Concrete batch plantCemex West Sacramento The fabricator/manufacturer designation for the sampleCemex
A detailed description of where the material sample was collectedConcrete Truck Tailgate Where the material sample would have been placed if not sampledCIDH Sign Foundation
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-06-10-63-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcretePhillip Asher III, CT D03 - Olivehurst Northern Regional Laboratory06/10/202406/13/2024
No
100+ Day; concrete truck had to come back around to get in.
2024-06-10-63-2ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcretePhillip Asher III, CT D03 - Olivehurst Northern Regional Laboratory06/10/202406/13/2024
No
CIDH Wet Hole Mix
2024-06-10-63-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory07/08/202407/08/2024
Yes
07/08/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-06-10-63-1 ASTM C1064-17
DIME Test ID: 2024-06-10-63-2 ASTM C143-15a
DIME Test ID: 2024-06-10-63-3 ASTM C39-17a (Verified)