Sample Record

DIME Sample ID 2024-06-11-30

Project Information

Project IdentifiersProject ID: 994864
DEA: 050N74U4
EFIS: 0522000025
DIST-CO-RTE-PM05-SB-101-9.9/10.6
Award Date07/10/2023
Closeout DateNot set
Work DescriptionSB 101 4D North San Ysidro to Olive Mill
Location DescriptionIn Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing
QA Service Level1 (Verified on 08/21/2023)

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

Sample Information

Sample Taken Date06/11/2024 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing06/11/2024 Sample typeQuality Assurance
A brief description of the sample1 x 4 PCC Aggregate The quantity of what the sample constitutes20 cy
From where was the sample collectedSupplier First name of sampler or witnessed byDoug
Last name of sampler or witnessed byRuff Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Padaro Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number231 R
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected16171
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-06-11-30-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteDoug Ruff, CT D05 - Carpinteria Field Laboratory06/11/202406/12/2024
Yes
06/12/2024Public - Test Data Visible
2024-06-11-30-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodDoug Ruff, CT D05 - Carpinteria Field Laboratory06/11/202406/12/2024
Yes
06/12/2024Public - Test Data Visible
2024-06-11-30-3CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteDoug Ruff, CT D05 - Carpinteria Field Laboratory06/11/202406/12/2024
Yes
06/12/2024Public - Test Data Visible
2024-06-11-30-4CTM 523-May 2020: Method of Test for Flexural Strength of ConcreteJesse Gomez, CT D05 - Carpinteria Field Laboratory07/09/202407/23/2025
Yes
07/23/2025Public - Test Data Visible
2024-06-11-30-5CTM 523-May 2020: Method of Test for Flexural Strength of ConcreteJesse Gomez, CT D05 - Carpinteria Field Laboratory06/24/202407/23/2025
Yes
07/23/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-06-11-30-1 ASTM C1064-17 (Verified)
DIME Test ID: 2024-06-11-30-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2024-06-11-30-3 CTM 533-June 2010 (Verified)
DIME Test ID: 2024-06-11-30-4 CTM 523-May 2020 (Verified)
DIME Test ID: 2024-06-11-30-5 CTM 523-May 2020 (Verified)