Sample Record

DIME Sample ID 2024-06-06-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995524
DEA: 021H3604
EFIS: 0216000040
DIST-CO-RTE-PM02-SIS-96-76.8/78.0
Award Date03/22/2024
Closeout Date12/29/2025
Work DescriptionREPLACE BRIDGE.
Location DescriptionSISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK
QA Service Level1 (Verified on 12/27/2023)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date06/06/2024 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing06/11/2024 Sample typeQuality Assurance
A brief description of the sampleASTM A706 Grade 60 Welded Hoops The quantity of what the sample constitutes1252
From where was the sample collectedFabricator First name of sampler or witnessed byArthur
Last name of sampler or witnessed byPeterson Title of samplerAssociate Steel Inspector
Telephone number of sampler707-342-8602 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC San Bernardino
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL110-079-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4138805
Hoop Manufacturer Lot Number(s)Lot no. 16 and Lot no. 19 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-06-06-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/13/202406/13/2024
Yes
06/14/2024Ok NeckingPublic - Test Data Visible
2024-06-06-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/13/202406/13/2024
Yes
06/14/2024Ok NeckingPublic - Test Data Visible
2024-06-06-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/13/202406/13/2024
Yes
06/14/2024Ok NeckingPublic - Test Data Visible
2024-06-06-2-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/13/202406/13/2024
Yes
06/14/2024Ok NeckingPublic - Test Data Visible
2024-06-06-2-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/13/202406/13/2024
Yes
06/14/2024Ok NeckingPublic - Test Data Visible
2024-06-06-2-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/13/202406/13/2024
Yes
06/14/2024Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-06-06-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-06-06-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-06-06-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-06-06-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-06-06-2-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-06-06-2-6 CTM 670-December 2013 (Verified)