Sample Record

DIME Sample ID 2016-10-03-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210759
DEA: 120N1104
EFIS: 1213000116
DIST-CO-RTE-PM12-ORA-101,154-9.5
Award Date01/05/2016
Closeout Date06/25/2019
Work DescriptionSTABILIZE SLOPE EMBANKMENT AND ROADWAY AT ROUTE 133/5 SEPARATION.
Location DescriptionIN ORANGE COUNTY IN IRVINE AT ROUTE133 / 5 SEPARATION.
QA Service Level1 (Verified on 06/20/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date10/03/2016 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing10/10/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchhill Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar
Transportation Laboratory (TL) NumberC970907 Inspector Lot Number from the Transportation Laboratory (TL) FormL0213816
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)PL14104777
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-10-03-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/11/201610/11/2016
Yes
10/12/2016necking okayPublic - Test Data Visible
2016-10-03-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/11/201610/11/2016
Yes
10/12/2016necking okayPublic - Test Data Visible
2016-10-03-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/11/201610/11/2016
Yes
10/12/2016Bar Broke in Heat Affected AreaPublic - Test Data Visible
2016-10-03-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/11/201610/11/2016
Yes
10/12/2016Bar Broke in Heat Affected AreaPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-10-03-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-03-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-03-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-03-5-4 CTM 670-December 2013 (Verified)