Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-10-05-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210570
DEA: 100Y90U4
EFIS: 1015000055
DIST-CO-RTE-PM10-SJ-99,15,163-18.4/23.0
Award Date12/04/2015
Closeout Date04/11/2017
Work DescriptionPLACE JPCP (RSC), COLD PLANE AC PAVEMENT, AND INSTALL RAMP METERING.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.1 MILE SOUTH OF MARSH STREET PEDESTRIAN OVERCROSSING TO 0.1 MILE NORTH OF HAMMER LANE OVERCROSSING
QA Service Level1 (Verified on 09/23/2015)

Sample Information

Sample Taken Date10/05/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMission City Rebar Transportation Laboratory (TL) NumberC836024
Inspector Lot Number from the Transportation Laboratory (TL) FormB914016 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE16101751
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop1'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerMission City Rebar
Welding CompanyMission City Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-10-05-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/2016Brian
Yes
10/12/2016Bar Broke in Heat Affected Area
2016-10-05-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/2016Brian
Yes
10/12/2016necking okay
2016-10-05-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/2016Brian
Yes
10/12/2016necking okay
2016-10-05-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/2016Brian
Yes
10/12/2016necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-10-05-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-05-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-05-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-10-05-5-4 CTM 670-December 2013 (Verified)