Sample Record

DIME Sample ID 2024-05-10-41

Project Information

Project IdentifiersProject ID: 994812
DEA: 042K7204
EFIS: 0417000014
DIST-CO-RTE-PM04-CC-4-R14.3/24.3
Award Date03/23/2023
Closeout Date10/06/2025
Work DescriptionPvmt rehabilitation, slab repl, ADA curb ramp and install guardrail.
Location DescriptionOn state highway in Contra Costa County in and near Concord and Pittsburg from 0.3 miles east of Peralta Road Undercrossing to Loveridge Road Overcrossing.
QA Service Level1 (Verified on 05/10/2023)

Owner Lab

  • CT D04 - Concord Field Laboratory

Sample Information

Sample Taken Date05/10/2024 Sample Unique Key41
Date that the sample was received by the laboratory/organization performing the testing05/15/2024 Sample typeQuality Assurance
A brief description of the sample3/4-INCH RHMA-G The quantity of what the sample constitutes6300 Grams
From where was the sample collectedSupplier First name of sampler or witnessed byNick
Last name of sampler or witnessed byHALL Title of samplerLab Technician
Telephone number of sampler7072999133 Laboratory sample identificationCon_24_332
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Vernalis Drier Drum Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0041
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Stream @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number4
Sublot number17 Aggregate Mix Number30240532510A

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-05-10-41-1AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Jacob Vega, CT D04 - Concord Field Laboratory05/15/202405/23/2024
Yes
05/24/2024LOT 4 SUBLOT 17 Teichert Vernalis Drier Drum Plant Public - Test Data Visible
2024-05-10-41-2AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Jacob Vega, CT D04 - Concord Field Laboratory05/15/202405/23/2024
Yes
05/24/2024Teichert Vernalis Drier Drum Plant LOT 4 SUBLOT 17 Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-05-10-41-1 AASHTO T176-08 (Verified)
DIME Test ID: 2024-05-10-41-2 AASHTO T27-14 (Verified)