Sample Record

DIME Sample ID 2016-09-29-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211723
DEA: 120N8804
EFIS: 1214000126
MINOR: 12A1641
DIST-CO-RTE-PM12-ORA-405-1.12
Award DateNot set
Closeout Date06/21/2021
Work DescriptionReplace safety lighting standards and refresh Signing and Striping for the SB 405 off ramp at Irvine Center Drive
Location DescriptionIRVINE, SOUTHBOUND RTE 405, AT EXIT RAMP TO IRVINE CENTER DRIVE
QA Service Level1 (Verified on 09/12/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/29/2016 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing10/03/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes1
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchill Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar Nucor
Transportation Laboratory (TL) NumberC970905 Inspector Lot Number from the Transportation Laboratory (TL) FormL0213216
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14104777
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-09-29-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/04/201610/04/2016
Yes
10/05/2016Bar Broke in Heat Affected AreaPublic - Test Data Visible
2016-09-29-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/04/201610/04/2016
Yes
10/05/2016Bar Broke in Heat Affected AreaPublic - Test Data Visible
2016-09-29-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/04/201610/04/2016
Yes
10/05/2016Bar Broke in Heat Affected AreaPublic - Test Data Visible
2016-09-29-9-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory10/04/201610/04/2016
Yes
10/05/2016Bar Broke in Heat Affected AreaPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-29-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-29-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-29-9-3 CTM 670-December 2013 (Verified)