Sample Record

DIME Sample ID 2016-09-27-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209918
DEA: 07274804
EFIS: 0700000516
DIST-CO-RTE-PM07-LA-18-0.2
Award Date12/09/2014
Closeout Date01/15/2018
Work DescriptionREPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS.
Location DescriptionLOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD
QA Service Level1 (Verified on 01/08/2015)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/27/2016 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing09/30/2016 Sample typeQuality Assurance
A brief description of the sampleEpoxy Coated Rebar The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byJeff
Last name of sampler or witnessed bySulka Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWestern Coating
Transportation Laboratory (TL) NumberC970780 Inspector Lot Number from the Transportation Laboratory (TL) FormL8100516
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)PL16106027
Rebar Epoxy Batch Number(s)3315294 Rebar Coating SpecificationASTM A775
Rebar Size (#)#5 Rebar Coating ColorGreen
Rebar ManufacturerNucor Rebar CoaterWestern Coating
Rebar Powder ManufacturerAxalta Release NumberUnknown
Quality Assurance CodeUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-09-27-10-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/03/2016
Yes
10/05/2016Public - Test Data Visible
2016-09-27-10-3ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory10/03/2016
Yes
10/05/2016Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-27-10-2 ASTM A775-07b-re14 (Verified)
DIME Test ID: 2016-09-27-10-3 ASTM A775-07b-re14 (Verified)