Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2024-02-21-27

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994325
DEA: 044J4904
EFIS: 0415000356
DIST-CO-RTE-PM04-ALA-13-6.7/7.2
Award Date01/09/2023
Closeout Date11/27/2024
Work DescriptionCONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY.
Location DescriptionALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 10/14/2022)

Sample Information

Sample Taken Date02/21/2024 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/22/2024
Sample typeQuality Control A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes7 From where was the sample collectedJob Site
First name of sampler or witnessed byJames Last name of sampler or witnessed byPorter
Title of samplerField Technician Telephone number of sampler
Laboratory sample identificationMix 7SK5K1X425F Set 1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameEcoTerra Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number7SK5K1X425F
The truck number from where the sample was collectedLoad 1 Truck 1 The batch plant ticket number from where the sample was collected0
Concrete batch plant The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedN/B RTE 13, CIPSC, STA 148+35, Truck #1 Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-02-21-27-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos02/28/202405/15/2024
Yes
05/15/2024Public - Test Data Visible
2024-02-21-27-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos03/20/202405/15/2024
Yes
05/15/2024Public - Test Data Visible
2024-02-21-27-3CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteJames Porter, G3 Quality, Incorporated - Cerritos02/21/202405/15/2024
Yes
05/15/2024Public - Test Data Visible
2024-02-21-27-4CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteJames Porter, G3 Quality, Incorporated - Cerritos02/21/202405/15/2024
Yes
05/15/2024Public - Test Data Visible
2024-02-21-27-5CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodJames Porter, G3 Quality, Incorporated - Cerritos02/21/202405/15/2024
Yes
05/15/2024Public - Test Data Visible
2024-02-21-27-6CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteJames Porter, G3 Quality, Incorporated - Cerritos02/21/202405/15/2024
Yes
05/15/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-02-21-27-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-02-21-27-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-02-21-27-3 CTM 557-June 2020 (Verified)
DIME Test ID: 2024-02-21-27-4 CTM 518-June 2010 (Verified)
DIME Test ID: 2024-02-21-27-5 CTM 504-June 2010 (Verified)
DIME Test ID: 2024-02-21-27-6 CTM 556-January 2018 (Verified)