Sample Record

DIME Sample ID 2016-09-23-1

Project Information

Project IdentifiersProject ID: 210886
DEA: 050F7004
EFIS: 0500000049
DIST-CO-RTE-PM05-MON-68-R17.4/R18.0
Award Date01/22/2016
Closeout Date12/30/2019
Work DescriptionWIDENING BRIDGE
Location DescriptionIN MONTEREY COUNTY ON ROUTE 68 NEARSALINAS FROM 0.2 MILE EAST OFRESERVATION ROAD UNDERCROSSING TO SPRECKELS BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 02/01/2016)

Owner Labs

  • CT HQ - QASI Bay Area Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/23/2016 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/26/2016 Sample typeQuality Assurance
A brief description of the sampleUlitmate butt splice reinforcing bar hoop The quantity of what the sample constitutes1 lot
From where was the sample collectedFabricator First name of sampler or witnessed byStacey
Last name of sampler or witnessed byDavis Title of samplerQuality Assurance Inspector
Telephone number of sampler562-480-6984 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB362-048-16
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)SE15104148
Hoop Manufacturer Lot Number(s)H51 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop3'-4.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-09-23-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/201609/27/2016
Yes
09/28/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-09-23-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/201609/27/2016
Yes
09/28/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-09-23-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/201609/27/2016
Yes
09/28/2016Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-23-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-23-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-23-1-3 CTM 670-December 2013 (Verified)