Sample Record

DIME Sample ID 2024-04-15-73

Project Information

Project IdentifiersProject ID: 994325
DEA: 044J4904
EFIS: 0415000356
DIST-CO-RTE-PM04-ALA-13-6.7/7.2
Award Date01/09/2023
Closeout Date11/27/2024
Work DescriptionCONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY.
Location DescriptionALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 10/14/2022)

Owner Lab

  • CT D04 - Concord Field Laboratory

Sample Information

Sample Taken Date04/15/2024 Sample Unique Key73
Date that the sample was received by the laboratory/organization performing the testing04/18/2024 Sample typeQuality Assurance
A brief description of the sample1/2-INCH RHMA-G The quantity of what the sample constitutes1778 Grams
From where was the sample collectedSupplier First name of sampler or witnessed byNick
Last name of sampler or witnessed byHALL Title of sampler
Telephone number of sampler7072999133 Laboratory sample identificationCon_24_181
Linked DIME Sample ID The fabricator/manufacturer/facility nameDe Silva Gates Sunol Drier Drum Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number3 HMA Mix NumberMD 6668
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-04-15-73-1AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)Jacob Vega, CT D04 - Concord Field Laboratory04/18/202405/11/2024
Yes
05/13/2024LOT 1 SUBLOT 3 De Silva Gates Sunol Drier Drum Plant Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-04-15-73-1 AASHTO T308-10 (Verified)