Sample Record

DIME Sample ID 2016-09-09-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211004
DEA: 05330784
EFIS: 0512000076
DIST-CO-RTE-PM05-SLO-46-46.0/50.2
Award Date02/10/2016
Closeout Date10/15/2019
Work DescriptionCONVERT 2-LANE TO 4 LANE EXPRESSWAY.
Location DescriptionNEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD
QA Service Level1 (Verified on 01/08/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/09/2016 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing09/19/2016 Sample typeQuality Assurance
A brief description of the sampleHRC Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed bySalvadori
Last name of sampler or witnessed byHeredia Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameGerdau, HRC
Transportation Laboratory (TL) NumberC918903 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#10 Coupler Model500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterNA Rebar Hoop FabricatorNA
Coupler Component Heat/Lot Number(s)0K1753 Rebar Heat Number(s)6502452802
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-09-09-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/19/201609/19/2016
Yes
09/21/2016Brittel BrakePublic - Test Data Visible
2016-09-09-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/19/201609/19/2016
Yes
09/21/2016OK NeckingPublic - Test Data Visible
2016-09-09-8-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/19/201609/19/2016
Yes
09/21/2016OK NeckingPublic - Test Data Visible
2016-09-09-8-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/19/201609/19/2016
Yes
09/21/2016OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-09-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-09-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-09-8-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-09-8-4 CTM 670-December 2013 (Verified)