Sample Record

DIME Sample ID 2016-09-06-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211319
DEA: 100Y5714
EFIS: 1014000162
DIST-CO-RTE-PM10-STA-99-R17.3/M18.9
Award Date06/09/2016
Closeout Date04/09/2018
Work DescriptionINSTALL AUTOMATED WARNING SYSTEM AND CONSTRUCT MVP.
Location DescriptionSTANISLAUS COUNTY IN MODESTO FROM 0.5 MILE NORTH OF KANSAS AVENUE OVERCROSSING TO 0.4 MILE NORTH OF CARPENTER ROAD/BRIGGSMORE OVERCROSSING
QA Service Level1 (Verified on 06/23/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/06/2016 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing09/07/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byGreg
Last name of sampler or witnessed byThompson Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) NumberC836016 Inspector Lot Number from the Transportation Laboratory (TL) FormB911516
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)582535
Hoop Manufacturer Lot Number(s)H01 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerEVRAZ
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-09-06-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/08/201609/08/2016
Yes
09/08/2016necking okayPublic - Test Data Visible
2016-09-06-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/08/201609/08/2016
Yes
09/08/2016necking okayPublic - Test Data Visible
2016-09-06-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory09/08/201609/08/2016
Yes
09/08/2016necking okayPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-06-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-06-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-09-06-6-3 CTM 670-December 2013 (Verified)