Sample Record

Owner Lab

  • CT D07 - Plant Services

DIME Sample ID 2024-04-18-21

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date04/18/2024 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/19/2024
Sample typeDepartment Acceptance A brief description of the sampleRSC Aggregates
The quantity of what the sample constitutes2 bags of aggregate From where was the sample collectedSource
First name of sampler or witnessed byAvo Last name of sampler or witnessed byKarajian
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC.A. Rasmussen - Chatsworth yard Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0025
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-04-18-21-3CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesAvo Karajian, CT D07 - Plant Services04/19/2024Avo Karajian
Yes
04/23/2024
2024-04-18-21-4CTM 217-June 2011: Method of Test for Sand EquivalentAvo Karajian, CT D07 - Plant Services04/19/2024Avo Karajian
Yes
04/23/2024
2024-04-18-21-5CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven DryingAvo Karajian, CT D07 - Plant Services04/19/2024Avo Karajian
Yes
04/23/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-04-18-21-3 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-04-18-21-4 CTM 217-June 2011 (Verified)